Bowing and Bulging Wall

Bowing and Bulging Wall

The joint owners of this 4 storey semi-detached Victorian villas (converted into flats) reported visible bulging, dropping brickwork arches to the rear and gable solid brickwork walls and long cracks developed internally.

case study 5b62f1ba37a455.34142644 - Bowing and Bulging Wall

The Structural Problem

The Action Wall Ties surveyor inspection identified ineffective and inadequate restraining plus spreading of the of the brick arches as the root cause of the problem. This had allowed the main elevation brickwork to bulge outward and brick arches over the doors and windows to spread and drop causing the brickwork above to crack. It also caused long cracks in the internal plaster work of the flats.

Bronsbury front view - Bowing and Bulging Wall

This is a common problem with properties of this type and age. As well as damaging the structural integrity of the property it often makes doors and windows difficult to open and close as the frames are warped by the pressure of the sagging brickwork load above.

Restoring Structural Integrity

The introduction of remedial reinforcement to the masonry and lateral restraints was recommended to provide restraint and support to restore the brickwork’s integrity.

Specialist equipment developed by Action Wall Ties was used to install bed joint reinforcing beaming, stainless steel lateral restraints and pins within the structure of the property. This restored the structural integrity of the masonry without the need for any visible restraints.

The cracked mortar was raked out and repaired with new coloured sand, lime and cement mortar that was a match for the existing mortar’s colour and texture.

Action Wall Ties’ specialist knowledge allowed them to restore the property’s structural stability without the need for costly rebuilding work. Their specialist equipment also minimised the disruption for the residents.

Action Wall Ties (AWT) are specialists in masonry reinforcement and repair, providing professional solutions to a wide variety of structural problems including issues with bowing and bulging brickwork in Victorian properties. Contact us on 01227 721 255email us or use our contact form.

Action Wall Ties serve customers in North West London and the whole South East of England.

Rendered Victorian Terrace with Bulging and Sagging Brickwork

Victorian Terrace with Bulging and Dropping Brickwork

This Victorian terraced home with rendered brickwork in Walthamstow, East London was suffering with dropping and outward bowing of the brickwork.

case study 5ba50c25294103.83954636 - Rendered Victorian Terrace with Bulging and Sagging Brickwork

The Problem

This rendered Victorian terrace home in Walthamstow, London E17, was suffering with significant distortion of the masonry. It also had dropping and outward bowing movement of the brickwork on the upper floor.

The left hand side external brickwork had bulged outward from the centre first floor. Internal movement to the junction of the dividing wall and external wall was also noted.

If structural repairs are sought early enough, AWTs specialist repair techniques may allow for repairs without removing render/pebble dash finishes. However, due to the advanced structural issues with this property, it was necessary to remove the render.

 

barclay upper floor - Rendered Victorian Terrace with Bulging and Sagging Brickwork

The Solution

The first step, after the initial survey, was to carefully remove the render finish on the front elevation to expose the underlying brickwork. As well as giving access to the brickwork this also allowed for a secondary survey to ensure there were no further issues with the masonry.

Our remedial work included:

  • Bed Joint Reinforcement Beaming
  • Crack Stitching
  • Fenestration Lintel Repair
  • Lateral Restraints
  • Grout Tie Injection
  • Brickwork Repairs
  • Realignment and Pinning of the Coping Stones

The repair work was designed to reinstate the uniformity of the walls and provide restraint in order to restore the tensile strength of the brickwork. It was also necessary to reconnect the main elevational brickwork to the brick internal dividing and party walls.

Action Wall Ties used specialist drilling rigs that enable precision drilling. State-of-the-art stainless steel fixings were then installed within the framework of the building. These techniques have been designed to deal with the root cause of structural faults rather than just provide a short-term cosmetic fix.

Carefully matched coloured sand and cement mortar was used to make good the drill holes. As can be seen in the photo, there are no visible fixings once repair works are complete. The exposed brickwork is left clean, tidy and ready for repointing. The facade of the house can either be left as exposed brick or the render can be replaced if desired.

barclay render removed - Rendered Victorian Terrace with Bulging and Sagging Brickwork

AWT’s specialist skills allowed these serious structural faults to be repaired quickly and economically. No long and costly rebuilding work was required.

Action Wall Ties (AWT) are specialists in masonry reinforcement and repair. AWT can advise on structural repairs to properties with render, pebble dash and spar dash. We provide professional solutions to a wide variety of structural problems for home owners in East London as well as the rest of London, Kent, Surrey and Sussex. Contact us on 01227 721 255, email us or use our contact form.

Bulging and Cracking Ornate Bay Window

Bulging and Cracking Ornate Bay Window

This Victorian/Edwardian terraced home in Lewisham SE4 was suffering with structural defects that were causing cracks in the decorative work around the bay windows as well as bowing brickwork.

case study 5beed707e44378.75615674 - Bulging and Cracking Ornate Bay Window

The Structural Problem

The beautiful decorative moulding around the bay windows of this terraced home in South East London was cracking. Even more worryingly, the brickwork of the bay window was visibly bulging and rotating away from the main part of the house. Inside the house there were cracks appearing in the internal party wall.

Action Wall Ties were called in to find a permanent solution to the structural issues while preserving the period features of the property.

The Structural Repair Solution

The AWT’s survey team diagnosed inadequate restraint of the bay window and a point loading issue with the party wall. Reinforcement of the masonry and a redistribution of the load on the party wall was required.

AWT have an arsenal of techniques at their disposal that are not available to traditional builders. This allows them to repair structural defects without rebuilding works.

Following a thorough survey, the following techniques were selected to restore the structural integrity:

  • Bed Joint Reinforcement Beaming
  • Crack Stitching
  • Grout Tie Injection
  • Lateral Restraints
  • Concrete and Brickwork Repairs

The specialist tools and equipment developed by AWT allows them to repair structural defects without compromising the look of a period property such as this.

st asaphs after - Bulging and Cracking Ornate Bay Window

 

A twin diamond bladed machine with attached vacuum was used for precision drilling prior to the installation of rows of twin 8mm stainless steel corded joint reinforcements. This helped to redistribute the weight of the upper storey to those parts of the supporting structure best able to carry them. It also assisted in restraining diagonal cracking and bulging.

8mm stainless steel lateral restraints screwed into the floor joists’ bresummer beam and resin bonded to the masonry provided further lateral restraint.

Localised cracks in the brickwork were stitched together using stainless steel fixings embedded out of sight within the brickwork.

Any patches of defective masonry were cut away and the areas were repaired using Flexcrete – a specialist repair substrate.

The finishing touches included colour matching any replacement bricks and ensuring the pointing style and mortar mixture matched the existing texture and colour.

AWT’s specialist skills allowed these serious structural faults to be repaired quickly and economically without damaging the character of the period features.

Action Wall Ties (AWT) are specialists in masonry reinforcement and repair. We provide professional solutions to a wide variety of structural problems for home owners in Lewisham and the whole of London, Kent, Surrey and Sussex. Contact us on 01227 721 255email us or use our contact form.

Failing Bressummer Lintel Due to Brown Rot

Failing Bressummer Lintel Due to Brown Rot

This Victorian/Edwardian terraced property with a render finish in South East London was suffering from advanced brown rot in the wooden bay window lintel and floor joists.

case study 5bf81d745907c7.44944351 - Failing Bressummer Lintel Due to Brown Rot

The Structural Problem

Brown Rot had taken hold in the horizontal load bearing timber beam in the front bay window of this home in the Hither Green, SE13 area of London. The rot had also spread to the adjacent cantilevered floor joists.

The beam and joists were no longer strong enough to support the weight of the building. The bay window area of the property was becoming unstable. The brickwork was cracking and bulging.

If structural repairs are sought early enough or if the structural defect is localised, as in this case, AWTs specialist repair techniques may allow for repairs without removing the render. The small disturbed areas of render can then be made good with a concrete repair mortar system.

brown rot lintel - Failing Bressummer Lintel Due to Brown Rot

 

The Structural Repair Solution

Action Wall Ties acted quickly to firstly stabilise the structure to prevent further movement.

Before installing temporary supports and starting to uncover the Bressummer beam AWT installed Bed Joint Reinforcement Beaming both externally and internally. Box beams were also installed.

Bed Joint Reinforcement Beaming requires precision drilling and injection of stainless steel bars and Cementitious grout into the brickwork. No fixings are visible once the work is complete. Re-pointing with colour matched sand and cement mortar gives a neat finish.

This vital work redistributed the upper storey loads to those parts of the supporting structure which were best able to carry them. It also assisted in restraining any further diagonal cracking and bulging of the brickwork.

When the temporary supports were in place the bay window beam and rotten floor joist were replaced. With the structural integrity restored, this property can now continue to be a home for many years to come.

AWT can provide cost-effective structural repairs for a wide range of structural faults including rotting wooden beams. AWT can advise on structural repairs to properties with render, pebble dash and spar dash finishes. We operate not only in SE London but across the whole of London and the South East of England.

To book a time for one of our surveyors to visit your property, call us today on 01227 721255, email us at enquiries@actionwallties.co.uk or use our contact form to get in touch.

Distorted Flank Wall with Difficult Access

Distorted Flank Wall with Difficult Access

This traditionally built mixed retail and domestic mid-terraced property in Greenwich, SE10, had visible bulging of the side wall.

case study 5c0669e65efd61.54833021 - Distorted Flank Wall with Difficult Access

The Structural Problem

The side wall brickwork of this property in was visibly bulging outwards. Movement was also noted within the property with some visible cracks.

The property located in South East London had retail space on the ground floor with domestic residences on the upper floors. Access to the flank wall was hindered by an abutting pitched slate roof which made access difficult.

Front elevation - Distorted Flank Wall with Difficult Access

Action Wall Ties needed to devise a structural repair scheme that would provide a lasting repair with minimal impact on the retail space, the residential space and the neighbouring properties.

An alternative to long, disruptive and costly rebuilding work was required.

Greenwich cracks - Distorted Flank Wall with Difficult Access

The Structural Repair Solution

AWT needed to ameliorate the masonry defects and add tensile strength to reinstating the brickwork’s integrity. A three pronged strategy was used:

  • Bed Joint Reinforcement Beaming
  • Lateral restraints
  • Brickwork repairs and infill

AWT used carefully designed scaffolding to access the defective masonry while taking care to protect the slate roof of the neighbouring property.

The wall contained an arched window opening that has been boarded over internally. The old sash window was removed and the opening was bricked up with colour matched bricks. Any damaged bricks were replaced.

Internally the installation of timber noggins and lateral restraints provided restraint of the lateral movement of the masonry. The stainless steel lateral restraints were screwed directly into the timber studs and then resin bonded to the masonry to provide a permanent solution to the lateral movement.

AWT used their precision diamond drilling equipment to install rows of twin cord reinforcement, forming a deep masonry beam. This redistributes the weight of the upper storeys. It also acts as a restraint to diagonal cracking and bulging.

Repointing the disturbed mortar with colour matched mortar provided the finishing touch.

AWT provide cost effective masonry repairs to customers throughout London and the South East.

To book a time for one of our surveyors to visit your property, call us today on 01227 721255, email us at enquiries@actionwallties.co.uk or use our contact form to get in touch.

 

logo logo logo logo logo logo