Located in Wandsworth, SW8, this Victorian/Edwardian home had clearly visible dropping and cracking masonry around the ground floor bay window. Shortly after the initial inspection, the masonry failed and the brickwork of the bay window collapsed.

Previous attempts at repairs by re-pointing the brickwork were clearly visible but had failed to get to the root cause of the structural defect. AWT was able to stabilise the masonry before strengthening the structure and rebuilding the brickwork to provide a long-lasting repair.

Read our frequently asked questions about bay window structural repairs.

The Structural Problem

simple horizontal - Rebuild & Reinforce Collapsed Bay Window in SW London
London bay window collapsed - Rebuild & Reinforce Collapsed Bay Window in SW London
SW8 bay window collapsed - Rebuild & Reinforce Collapsed Bay Window in SW London
London bay window sagging - Rebuild & Reinforce Collapsed Bay Window in SW London
SW8 bay window sagging - Rebuild & Reinforce Collapsed Bay Window in SW London
Bay structural reinforcement - Rebuild & Reinforce Collapsed Bay Window in SW London
Bay structural strengthening - Rebuild & Reinforce Collapsed Bay Window in SW London
Collapsed Bay Window, London
Collapsed Bay Window, SW London
Sagging Bay Window, London
Sagging Bay Window, SW London
Bay Window Structural Reinforcement
Bay Window Structural Strengthening
 
simple horizontal - Rebuild & Reinforce Collapsed Bay Window in SW London

AWT was called in to survey this mid-terraced, period property in Greater London. The ground floor bay window masonry and brickwork arches had visible cracking, dropping and significant outward leaning. A large gap had opened up between the brickwork columns and the box sash windows. This serious lack of structural integrity was also causing the 1st floor brickwork to bulge.

The photos show the warning signs that owners of similar properties should look for that warn of serious structural defects in bay window brickwork and the risk of collapse.

Just 2 days after the initial survey, the ground floor right-hand column and arch, the front arch plus the supported external skin of brickwork collapsed. This left the brickwork above unsupported and at imminent risk of failure. Urgent action was required to avoid the collapse of the entire front elevation.

The root cause of the structural defects was a combination of aging and inadequate restraining.

The Structural Repair Solution

simple horizontal - Rebuild & Reinforce Collapsed Bay Window in SW London
Collapsing bay masonry - Rebuild & Reinforce Collapsed Bay Window in SW London
dropping bay arch - Rebuild & Reinforce Collapsed Bay Window in SW London
bay window gap - Rebuild & Reinforce Collapsed Bay Window in SW London
dropping bay masonry - Rebuild & Reinforce Collapsed Bay Window in SW London
rebuilding bay brick arch - Rebuild & Reinforce Collapsed Bay Window in SW London
rebuilding bay brickwork - Rebuild & Reinforce Collapsed Bay Window in SW London
after bay rebuilt - Rebuild & Reinforce Collapsed Bay Window in SW London
rebuild bay window - Rebuild & Reinforce Collapsed Bay Window in SW London
Collapsing Bay Masonry
Bay Window Arch Just Before Collapse
Gaps Around Bay Window Glazing
Warning Signs of Bay Window Masonry Collapse
Rebuilding Bay Window Brick Arch
Rebuilding Collapsed Bay Brickwork
After Bay Window Rebuilding
Rebuild of Bay Window Brickwork
 
simple horizontal - Rebuild & Reinforce Collapsed Bay Window in SW London

As is often the case, this property showed signs of previous failed attempts at repairing the defects using traditional building techniques. Re-pointing dropping and sagging brickwork provides only a temporary, cosmetic solution, it doesn’t repair the underlying structural issues.

The bay window brickwork required realignment, structural reinforcement and rebuilding all without compromising the original period features.

Temporary supports were installed to prevent further damage to the masonry. AWT’s specialist realigning cramping equipment was used to straighten the bowed brickwork.

The collapsed masonry was rebuilt with the original components where possible. Replacement bricks and mortar were colour matched. A steel spine was built into the columns during rebuilding to strengthen and restrain the brickwork.

AWT’s special diamond drilling methods were used to introduce stainless steel bed joint reinforcement to strengthen the brickwork and redistribute the weight of the brickwork above. Grouted anchor fixings, lateral restraints and resin bonded ties were also installed to reinstate the strength and uniformity of the wall. The chipped and cracked window cills were also repaired using Flexcrete.

The result was a restoration of not only the structural strength of the bay window but also the preservation of the period features.

AWT provide cost effective structural repairs for a wide range of structural issues including failing and collapsed bay windows. We operate not only in SW London but across the whole of London and the South East of England.

To book a time for one of our surveyors to visit your property or to discuss your requirements, call us today on 01227 721255, email us at enquiries@actionwallties.co.uk or use our contact form to get in touch.

Call us if your building has any of these

Common Structural Defects, Issues or Problems

Our specialist structural repair contractors will be happy to help provide a comprehensive and permanent repair to your structural problems.

logo logo logo logo logo logo